Skip to Main Content
Search distributed energy resources in New York

Home Depot Camillus #1257

Overview Home Depot Camillus #1257

The project snapshot page provides a quick overview of the performance of the DER project. Hover over individual key performance indicators to see a definition.

Performance Snapshot

Sep 2018 to Aug 2021
4,767
MWh
electricity generated
Capacity
Factor
32,095
Mcf
generator fuel consumed
Electric
Efficiency
0
MMBtu
heat used
Thermal
Efficiency
CHP
Efficiency

The project monthly summary table provides measured data and key performance indicators for the DER project.

To view data for another date range, select your desired months and press “Go”.

To download data from the monthly summary table in CSV format, press the download button to the top right of the table.

Automated data filtering can be enabled or disabled via the control. Filtered data automatically checks to determine if the energy streams measured are consistent with each other (e.g. fuel consumption or heat recovery are reported only when a DER is reporting generated power). Disabling this control shows all data available.

Summary Table

Sep 2018 to Aug 2021
Electricity Generated (kWh) Total Fuel Consumed (cf) Total Heat Used (MBtu) Heat Rejected (MBtu) Capacity Factor (%) Electric Efficiency (% HHV) Thermal Efficiency (% HHV) CHP Efficiency (% HHV)
Total 4,767,106 32,095,391 0 0 86.7 49.1 0.0 49.1
Sep 2018
115,787 727,263 0 0 92.0 52.7 0.0 52.7
Oct 2018
147,908 927,540 0 0 94.7 52.7 0.0 52.7
Nov 2018
141,478 895,842 0 0 93.6 52.2 0.0 52.2
Dec 2018
145,472 916,674 0 0 93.1 52.5 0.0 52.5
Jan 2019
123,907 783,839 0 0 79.3 52.3 0.0 52.3
Feb 2019
133,871 830,598 0 0 94.9 53.3 0.0 53.3
Mar 2019
147,675 919,084 0 0 94.5 53.1 0.0 53.1
Apr 2019
138,170 878,011 0 0 91.4 52.0 0.0 52.0
May 2019
144,830 922,276 0 0 92.7 51.9 0.0 51.9
Jun 2019
139,679 895,250 0 0 92.4 51.6 0.0 51.6
Jul 2019
143,586 924,802 0 0 91.9 51.3 0.0 51.3
Aug 2019
140,063 916,674 0 0 89.6 50.5 0.0 50.5
Sep 2019
130,854 876,035 0 0 86.5 49.4 0.0 49.4
Oct 2019
142,051 934,811 0 0 90.9 50.3 0.0 50.3
Nov 2019
125,385 839,952 0 0 82.9 49.4 0.0 49.4
Dec 2019
137,341 934,526 0 0 87.9 48.6 0.0 48.6
Jan 2020
137,126 934,314 0 0 87.8 48.5 0.0 48.5
Feb 2020
127,795 873,731 0 0 87.4 48.4 0.0 48.4
Mar 2020
137,354 933,839 0 0 87.9 48.6 0.0 48.6
Apr 2020
133,106 903,917 0 0 88.0 48.7 0.0 48.7
May 2020
137,124 934,177 0 0 87.8 48.5 0.0 48.5
Jun 2020
132,350 904,139 0 0 87.5 48.4 0.0 48.4
Jul 2020
134,464 931,746 0 0 86.1 47.7 0.0 47.7
Aug 2020
134,226 930,435 0 0 85.9 47.7 0.0 47.7
Sep 2020
131,144 902,765 0 0 86.7 48.0 0.0 48.0
Oct 2020
135,260 934,177 0 0 86.6 47.9 0.0 47.9
Nov 2020
129,507 900,630 0 0 85.7 47.6 0.0 47.6
Dec 2020
131,987 931,122 0 0 84.5 46.9 0.0 46.9
Jan 2021
130,567 931,196 0 0 83.6 46.4 0.0 46.4
Feb 2021
116,183 839,677 0 0 82.3 45.8 0.0 45.8
Mar 2021
124,544 889,743 0 0 79.7 46.3 0.0 46.3
Apr 2021
117,328 833,737 0 0 77.6 46.5 0.0 46.5
May 2021
123,614 882,673 0 0 79.1 46.3 0.0 46.3
Jun 2021
118,095 851,652 0 0 78.1 45.9 0.0 45.9
Jul 2021
117,379 863,278 0 0 75.1 45.0 0.0 45.0
Aug 2021
119,897 865,265 0 0 76.7 45.8 0.0 45.8

Production data is not in real time and may be delayed as data is periodically reported and uploaded to this website.

Data Displayed:

The monthly summary plot shows monthly sums of measured data and monthly averages of key performance indicators.

To view data for another date range, select your desired months and press “Go”.

To download data used to create the monthly summary plot in CSV format, press the download button to the top right of the chart.

Automated data filtering can be enabled or disabled via the control. Filtered data automatically checks to determine if the energy streams measured are consistent with each other (e.g. fuel consumption or heat recovery are reported only when a DER is reporting generated power). Disabling this control shows all data available.

Click on legend entries below the plot, if present, to show or hide data.

Data Displayed

Production data is not in real time and may be delayed as data is periodically reported and uploaded to this website.

Data Displayed:

The time series plot shows averages of measured data and key performance indicators. The plot can be switched between the daily and hourly time steps, to adjust the level of averaging displayed.

To view data for another date range or time step, select your desired dates and time step and press “Go”. Due to performance constraints, hourly data may only be displayed within a date range of up to one month in length.

To download data used to create the time series plot in CSV format, press the download button to the top right of the chart.

Automated data filtering can be enabled or disabled via the control. Filtered data automatically checks to determine if the energy streams measured are consistent with each other (e.g. fuel consumption or heat recovery are reported only when a DER is reporting generated power). Disabling this control shows all data available.

Click on legend entries below the plot, if present, to show or hide data.

Data Displayed

Times are shown in Eastern Time (ET) and are adjusted to reflect Daylight Saving Time (DST).

Production data is not in real time and may be delayed as data is periodically reported and uploaded to this website.

Data Displayed:

The ambient temperature plot shows averages of measured data and key performance indicators versus ambient temperature.

To view data for another date range or time step, select your desired dates and time step and press “Go”. Due to performance constraints, hourly data may only be displayed within a date range of up to one month in length.

To download data used to create the ambient temperature plot in CSV format, press the download button to the top right of the chart.

Automated data filtering can be enabled or disabled via the control. Filtered data automatically checks to determine if the energy streams measured are consistent with each other (e.g. fuel consumption or heat recovery are reported only when a DER is reporting generated power). Disabling this control shows all data available.

Click on legend entries below the plot, if present, to show or hide data.

Data Displayed
Ambient Temperature data provided by NOAA at weather.govLink opens in new window - close new window to return to this page.

Production data is not in real time and may be delayed as data is periodically reported and uploaded to this website.

The project performance benchmark page shows how the DER project performs compared to similar-sized projects using the same technology in the same facility category. The key performance index used for benchmarking can be changed by selecting the desired rating from the table headings at the bottom of the page. Clicking on each result in the distribution will bring up the name and link to other related facilities.

To view data for another date range, select your desired months and press “Go”.

Note that benchmarking only occurs on data with automated data filtering on, to ensure consistent ranking results.

CHP
Efficiency
Thermal
Efficiency
Electric
Efficiency
Capacity
Factor
Electric
Generation
Home Depot Camillus #1257 49.1 % 0.0 % 49.1 % 86.7 % 4,767 MWh
Top Peer 49.1 % 0.0 % 49.1 % 86.7 % 4,767 MWh
Average Peer — % — % — % — % — MWh

Peer Criteria

  • Technology: Fuel Cell
  • Generation Capacity: Small (0-250 kW)
  • Facility Category: Mercantile (Retail Other Than Malls)
  • Total Peers in Group: 0

Use this page to download all measured performance data for a DER project in CSV format. Select your desired date range and time step, then press the “Download” button to save the data file to your computer.

Download Data

To download performance data, select your desired date range and time step, then click the Download button.

Production data is not in real time and may be delayed as data is periodically reported and uploaded to this website.